Thursday, May 24, 2012

SRCB (Residual Current operated Circuit Breakers with integral Overcurrent protection)


http://www.entekelectric.com
info@entekelec.com

SRCB (Residual current operated Circuit Breakers with integral Overload protection) protect damage caused by leakage current in additional to the protection of MCB

Features

  • Overload protection is provided by calibrated thermal element.
  • Short circuit protection is provided by magnetic trip mechanism.
  • Earth leakage protection is provided by balance core sensing device.
  • 6 kA & 10 kA Breaking Capacity: SRCBs have a high breaking capacity throughout the range. They operate on current limiting principle ensuring extremely low let through energy under fault conditions.
  • Trip Free Mechanism: The SRCB trips positively even when it's locked in on position.
  • Safety Terminals: The terminals are touch proof ensuring maximum operator safety against accidental contact (IP20 of protection).
  • Energy Saver: The watt loss of the SRCBs is extremely low providing valuable savings over its entire lifecycle.
  • Single pole with one over-current protected pole and uninterrupted neutral.
  • Sensitivity non-adjustable.

Technical Specifications

  • Rated Current: In 10A, 16A, 20A
  • Voltage:  120/240 V AC
  • Sensitivity: 10mA, 30mA, 100mA, 300mA 
  • Short Circuit Capacity: 6kA & 10 kA

Tuesday, May 8, 2012

Single Module RCBO's (MCB/RCD)


http://www.entekelectric.com
info@entekelec.com


RCBO (Residual current operated Circuit Breakers with integral Overload protection) protect damage caused by leakage current in additional to the protection of MCB


Features

  • 6kA & 10kA breaking capacity: RCBOs have a high breaking capacity throughout the range. They operate on current limiting principle ensuring extremely low let through energy under fault conditions.
  • Trip free mechanism: The RCBO trips positively even when it's locked in on position.
  • Safety terminals: The terminals are touch proof ensuring maximum operator safety against accidental contact (IP20 of protection).
  • Uniform components profile: The RCBOs have a uniform profile and can be connected through pin type & fork type busbars. Bottom terminal for fork type busbar is isolated between the poles.
  • Energy Saver: The watt loss of the RCBOs is extremely low providing valuable savings over its entire lifecycle.
  • Functionality depends on line voltage.
  • Single pole with one over-current protected pole and uninterrupted neutral
  • Sensitivity non-adjustable

Technical Specifications

  • Standards: EN61009-1
  • Rated Current: In 10A, 16A, 20A, 25A, 32A
  • Voltage:  230V AC
  • Sensitivity: 10mA, 30mA, 100mA, 300mA 
  • Module Width: 1 x 18 mm
  • Module Length: 110 mm
  • Magnetic range: Curve C - 5(In) to 10 (In)
  • Connection Type: Cable, Busbar (Fork & Pin)
  • IP Rating: IP20
  • Operating Temperature range: -5° C to +40° C Ambient
  • Rated Insulation Voltage (Un): 500V
  • Impulse Withstand Voltage (Vimp): 2.5 kV
  • Mounting: DIN RAIL 35mm

Dimensions (mm)


Compatible with ABB, Schneider, Eaton, Hager, Moeller, Square D, Crabtree, Merlin Gerin RCBOs.

Thursday, May 3, 2012

MCB (Miniature Circuit Breaker)

Website: http://www.entekelectric.com
E-mail: info@entekelec.com


Miniature circuit breakers protect electrical circuits from damage caused by overload or short circuit via the protection of thermal type trip and magnetic trip. 

MCB
Entek's MCB - KB

Features

  • 6kA & 10kA breaking capacity: These MCBs have a high breaking capacity throughout the range. They operate on current limiting principle ensuring extremely low let through energy under fault conditions.
  • Trip free mechanism: The MCB trips positively even when it's locked in on position.
  • Terminal Design: Double function terminal design for accepting both busbar and conductors simultaneously.
  • Safety terminals: The terminals are touch proof ensuring maximum operator safety against accidental contact (IP20 of protection).
  • Uniform components profile: The MCBs have a uniform profile and can be connected through pin type & fork type busbars. Bottom terminal for fork type busbar is isolated between the poles.
  • Accessories: Common modular accessories like Shunttrip, Motor mechanism, Undervoltage release and Auxiliary contacts ensure flexibility.
  • Energy saver: The watt loss of the MCBs is extremely low providing valuable savings over its entire lifecycle.

Technical Specifications

  • Standards: IEC60898
  • Rated Current: In 6, 10, 16, 20, 25, 32, 40, 50, 63
  • Number of poles: 1, 2, 3
  • Rated Operational Voltage: Ue 230/400V AC
  • DC Application: 48V per pole
  • Frequency: 50 - 60 Hz
  • Tripping Characteristics: B, C curve
  • Operating Temperature range: -5° C to +55° C Ambient
  • Mounting Arrangement: Snap on fixing, 35mm Din channel
  • Terminal Size: Suitable for 35mm cable
  • Shock resistance (x, y & z dir): 40g, duration of 5 ms
  • Vibration resistance (x, y & z dir): 3g, operating time at least 30 mins
Dimensions (mm)
  • Dimensions of 2, 3 pole MCBs are multiples of single pole MCB dimensions, as these are modular units.
  • The KB series of MCBs is the most popular model in the market and is compatible with our RCBOs and other well known brands worldwide.

Compatible with ABB, Schneider, Eaton, Hager, Moeller, Square D, Crabtree, Merlin Gerin MCBs (Miniature Circuit Breakers)